Product Description
Micro-wave video X-ray pipeline crawler
Features:
1 X-ray Generator system has a regulatory function of KV with large diameter and thick walled tube has the regulatory function. Tran illumination to ensure the X-ray film and degree of consensus.
2 Electronic speed control motor function, to achieve constant torque, constant current operation, could be 40 percent energy saving at the same time motor over current protection.
3Automatically inspect the energy of battery. When the voltage of battery is not enough, the crawler will turn back in time .
4It has various real-time function to protect the x-ray generator in case of meeting water, over-voltage, zero voltage, over-current, zero current, meeting barrier, antenna falling off, X-ray generator falling off, over temperature.
5 Instead of ?-source location, it adopts radio microwave video location, which is safer, more direct-viewing, and location-accurate.
6 It has a continuous contact with runner in order to show the inner situation clearly. e.g.: NDT Equipment fault, battery State LOW, over tempered inner pipeline, distance to the pipe mouth.
7 It has the automatic stop function, with no need of Real Time Monitoring.
Main Technical specifications
Model ZY-2 ZY-3 ZY-4 ZY-2C
Limit of applicable pipe-diameter (mm) F406-1200 F323-529 F219-355 F508-1400
Outline dimension of creeping instrument (mm) 1410×300×195 1531×210×195 1230×180×195 1150×300×260
Dimension of instruction controller (mm) 420×360×160 420×360×160 420×360×160 420×360×160
Weight (Kg) 80(100) 60 50 100
Creeping Speed (m/min) 12-15 12-15 12-15 13-16
Location error (mm) ±3 ±3 ±3 ±5
Maxima climbing slope 0°-25° 0°-25° 0°-25° 0°-25°
Ray radiation angle 360°×25° 360°×25° 360°×25° 360°×25°
Operate temperature -20?-60? -20?-60? -20?-60? -20?-60?
Relative humidity 90% 90% 90% 90%
pipeline crawler configuration
No. Item Quantity
1 Climb car 1
2 X-ray Generator system 1
3 Command controller 1
4 Battery and cell box 1
5 Changer 1(120V)
6 Supporting plate 2
7 CCD camera 1
8 lifter slide 2
9 connecting cable 2
10 Short sleeves adapting
11 Extension Shaft adapting
Magnetic medium control X-ray pipeline crawler
Features:
1 Ease start, Low-state positioning. To ensure accurate positioning at the same time, extend equipment life.
2 Features with going through the welding machine, without impacting of the welding machine, good for normal work .
3 X-ray Generator system has a regulatory function of KV, Transillumination to ensure the X-ray film and degree of consensus.
4Electronic speed control motor function, to achieve constant torque, constant current operation, could be 40 percent energy saving at the same time motor overcurrent protection.
5Automatically inspect the energy of battery. When the voltage of battery is not enough, the crawler will turn back in time .
6It has various real-time function to protect the x-ray generator in case of meeting water, over-voltage
Company Profile
|
Business Type: |
We are manufacture of x ray ndt equipment,pipeline crawler,industrial led film viewer ,x ray tubes,HV winding, and measuring instrument. |
|
Comapany: |
Dandong zhongyi electronic co.,ltd |
|
Year of Establishment: |
2000 |
|
Branches: |
Zhongyi |
|
Address: |
NO5 Tongxing Street |
|
City: |
Dandong |
|
Zip/Postal: |
118011 |
|
State: |
Liaoning |
|
Country: |
China |
.