Product Description
1.LCD display, blue backlight, suitable for dark places
2.Automatic Shutdown
3.Press HOLD key to keep data
Technical Specification
1.Base Conditions and Working Conditions
- - - -
Influence Quantity | Base Condition | Working Conditions | Remark |
Ambient Temp | 23°C±1°C | -10°C~40°C | |
Ambient Humidity | 40%~60% | <80% | |
Signal Waveform | sine wave | sine wave | ß=0.05 |
Signal Frequency | 50HZ±1HZ | 45HZ~65HZ | |
Meter Working Volt | 9V±0.1V | 9V±1V | |
External Electric, Magnetic Field | To be avoided |
Measured Wire Position | Measured wire at approximately the geometric center of the clamp |
- - - -
2.General Specification
- - - -
Function | Phase, AC current, AC voltage, AC leakage current, direct test of phase sequence; transformer groups, inductive, capacitive circuit discrimination; indirect test of power factor and power |
Power | DC9V alkaline batteries(1.5V AA×6) |
Consumption | About 35mA at most with enabled backlight, battery working continuously for about 40 hours |
-3- About 5mA with disabled backlight, battery working continuously for about 300 hours |
Display Mode | LCD display, blue backlight, suitable for dark places |
LCD Size | 70mm×62mm |
LCD Display Field | 64mm×54mm |
Meter Size | Length, Width, Height:196mm×92mm×54mm |
Clamp Size | f7.5mm×13mm |
Sampling Rate | About 3 times/second |
Measurement Range | AC Voltage:0~20V/200V/500V |
AC Current:0~200mA/2A/10A |
Phase:0~360° |
Measured Signal Amplitude in Phase Test | U1-U2 phase test:30V~500V |
I1-I2 phase test:10mA~10.00A |
U1-I2 or I1-U2 phase test:10V~500V, 10mA~10.00A |
Data Hold | Press HOLD key to keep data, "DH" symbol appears |
Automatic Shutdown | Automatic shutdown about 15 minutes later after launching to reduce battery consumption |
Voltage Detection | Low battery symbol “ " appears to remind the replacement of battery when the battery voltage drops below 7.8V~8V. |
Weight | Main Unit about 550g(with battery), clamp about 170g×2, test line about 250g |
Test Line Length | 1.5m |
Current Clamp Length | 2m |
Working Temperature and Humidity | -10°C~40°C;below 80%Rh |
Storage Temperature and Humidity | -10°C~60°C; below 70%Rh |
Input Impedance | Input impedance for all test voltage range:2MO |
Input impedance when testing U1U2 phase:40KO |
Withstand Voltage | Withstand 1000V/50Hz sine wave AC voltage for 1 minute between the meter lines and shell; Withstand 500V/50Hz AC voltage sine wave for 1 minute between the two voltage inputs |
Insulation | =10MO between meter lines and shell or between the two voltage inputs |
Structure | -4- Double insulation |
- - - -
3.Intrinsic error and
Company Profile
|
Business Type: |
As an Asian Electronics Sales, Marketing and Design Solution company, Bestern Asia industrial Limited was founded in 2007 in HK. We mainly focus on OEM and ODM customers base, provide supply chain service in the region of Greater China, and face all ... |
|
Comapany: |
Bestern asia industrial limited |
|
Address: |
High-tech InnovationPark, Baoan |
|
City: |
Shenzhen |
|
Zip/Postal: |
518000 |
|
State: |
Guangdong |
|
Country: |
China |
As an Asian Electronics Sales, Marketing and Design Solution company, Bestern Asia industrial Limited was.