Product Description
Maximum flexibility, comfort and safety: KNX
KNX is a fieldbus, a development of the EIB, and serves the networking of individual components for building automation. Thus, as lighting, heating, ventilation and air conditioning, alarm and monitoring systems, interfaces, maintenance and building monitoring, etc. are governed by a unified system. KNX on different apparatus (via twisted pair, radio, 230 volt power, IP / Ethernet) connected. Data are then - regardless of manufacturer or type of application - between the individual components interchangeable. The individual components are at any time, including retroactively, configurable. This type of individual lighting control creates a high cost and need adjustment.
IR Remote Controls
As an accessory to our presence detectors are 2 special IR remote controls are available. This means that the settings easily, lighting, dimming, as well as store and retrieve up to four scenes by the room user. The brightness measurement can be calibrated remotely detector parameters changed without the use of the ETS software and a test operation to be started and stopped. Via IR remote control parameters are changed in the version of the KNX bus read.
The interfaces COM1 and COM1 A are available for the following sensors:
? IR Quattro
? IR Quattro HD
HF 360
? DUAL HF
Fitted out with KNX presence detector interface of the Control Systems PRO can accept the following functions:
Presence message
Lighting control with brightness control
HVAC control
Presence-message
function allows the monitoring of the area. Once the presence of a person was reliably detected and when no presence is detected more, this will be reported directly. This monitoring function can be locked during the day and only during a certain period of time over the weekend and released at night for example.
Lighting control
The lighting control switches - depending on one, and presence of ambient light - the light when it is needed and off when it is no longer needed. The light is only switched on when it is needed. Unnecessary energy consumption, and unnecessary costs are avoided.
HVAC control
Systems for heating, ventilation and air conditioning are controlled by the main HVAC. This shows only a function of presence, there will also be at sufficient natural heating, ventilation and air conditioning available. If the room is no longer used, even to heating, ventilation and air conditioning energy and off economically.
Modes of the presence detector
One of the following modes must be assigned to the presence detector:
Single detector
Main detector
Nebenmelder Masters
Main master in parallel
in addition to master parallel
Single detector
It is only a single presence detector installed in the room.
Master
To extend the presence coverage you can connect up to four additional presence detector (slaves) on the bus with the master. The main detector determines the overall presence (a person is in at least one of the detection ranges?), Performs for the entire ro