Product Description
CE Portable Fetal Maternal Monitor BFM-700M TFT ( Multi-parameter )
Feature:
BFM-700A is single fetal / maternal monitor.
BFM-700M is fetal / maternal monitor for twins.
5.7 inches TFT LCD displays US and UC data, mother's NIBP, TEMP, RR, SpO2, and ECG main parameters and monitoring trace curve etc.;
FHR collects signal indication, alarm indication for abnormal FHR, fetal movement indication, and can freeze monitoring status;
Can set the time limit (0-99 minutes), automatically entering dormant state if no signal input;
Store monitoring data for 24 hours, with replay function;
Coding keyboard adjusts all parameters setting of the unit, convenient to use;
Adopt 832 thermal linear array printer, store the data and print rapidly; and printing width is 112mm;
The printer parameters can be adjusted according to user needs, including printing paper speed, trace line thickness, signal sampling rate, upper and lower alarming limit, real time, and date;
Set-up data and parameters can be automatically saved after power off;
The monitoring data can be conveyed to exterior computer through RS-232 or USB port;
Trolly (adjustable) for option, convenient to move and operate.
Specifications:
1. US:
Transducer : 9 crystals, wide wave beam
Working mode: Pulsed ultrasound Doppler
Ultrasonic frequency: 1.0MHz±10%
Measuring range: 50-240 BPM
Alarm range: Up: 55-240 BPM Adjustable continuously within range
Low: 50-235 BPM Adjustable continuously within range
2. TOCO:
Display range: 0-100units (non-linear error: =±10%)
3. PC PORT:
Edition USB 1.1 or USB 2.0; RS-232
4. THERMAL RECORDER:
Paper width : 112 ± 2mm ;effective record width : 105 ± 2mm; Paper length : 15m
Recorder density : US: 27 BPM/ CM ; UC: 40 BPM / CM
Printing speed (adjustable): 1 cm/min, 2 cm/min, 3 cm/min
5. POWER and BATTERY:
Battery: 16.8V Ni-MH rechargeable batteries group; AC 220 /110 V ; Consume power: = 60 W
Continuous working time in static condition: = 1 hours
6.ECG and HR:
Measuring range: 30 BPM -350 BPM
Cardiac electric noise level: = 30 µV
Cardiac electric frequency response:
Filtering mode: 1-25 MHz
Non-filtering mode: 0.05-100 MHz
Cardiac electric Input loop current: = 0.1 µA
7.NIBP:
Measuring range:
a) SBP: (8.0—34.0) kPa or (60—255) mmHg
b) DBP: (4.0—26.0) kPa or (30—195) mmHg
c) MAP: (5.3—28.7) kPa or (40—215) mmHg
Automatic measuring interval: 3 min-99 min adjustable continuously within range
interval error: = ±10 s
8.RR:
Measuring range: 0 BPM-100 BPM
9.TEMP:
Channels: 1
TEMP probe: surface probe 1pcs
Measuring range: 28?-45 ?
Response time: =30s
10.SpO2:
Measuring range: 0-99%
11.PR:
Measuring range: 30-250 BPM
12.ENVIROANMENT REQUIREMENT:
Working Temperature: +5 ?-40 ? Humidity: =80% Atmospheric pressure: 86

Loading ..
Company Profile
|
Business Type: |
Our company has 8 series products: BF series Ultrasonic Fetal Doppler; BV series Ultrasonic Vascular Doppler; BFM series Fetal/Maternal Monitor;BPM series Multi-Parameter Patient Monitor; BD series Disposable Syringe Destroyer; ECG series, BEU series... |
|
Comapany: |
Shenzhen bestman instrument co,.ltd |
|
Year of Establishment: |
2001 |
|
Address: |
2nd Industrial Area of nanyou,nanshan |
|
City: |
Shenzhen |
|
Zip/Postal: |
518054 |
|
State: |
Guangdong |
|
Country: |
China |
Founded in 2001 as a high-tech company, Shenzhen Bestman Instrument Co., Ltd. has been devoting to research, manufacturing and distribution of medical instruments. Nowadays a great variety of products have been gained high popularity in home and abroad in medical line.
Our company has 8 series products: BF series Ultrasonic Fetal Doppler; BV series Ultrasonic Vascular Doppler; BFM series Fetal/Maternal Monitor;BPM series Multi-Parameter Patient Monitor; BD series Disposable Syringe Destroyer; ECG series, BEU series Ultrasound Scanners and BFW series Medical Fluid Infusion Warmer.
BF500/500+/500++/500A/500B/500C/500D/500D+/510/510S/530/530A/530B/
560/560A/560B/600/600+ series Fetal Doppler are specially designed to detect the Fetal Heart beat Rate (FHR) from the twelfth week of gestation, with earphone socket etc; BF-500 series are compact, light and easy to operate; BF-510/510S are pocket Doppler for home use; BF-600+ with LED display.Different models have respective functions and applications.
BF-610/610P/610M can be used both as fetal heartbeat detectors and monitors. LCD screen can display heartbeat rate signal indication synchronously, BF-610P/610M with printer can record synchronous FHR monitoring curve.
BV-520/520T/620/620VP Vascular Doppler Detector can detect the blood stream status of artery / vein, the blood stream of average speed, and the effect of fingers/toes and part of body's vein operation. BV-620VP can record synchronous blood stream curve.
BFM-610M/ 700/700E/700+/700E+/700A/700M series can monitor and display FHR with LED/LCD for single or twins, mother's TOCO, FHR curve, SpO2, NIBP, temperature, ECG and respiration etc; they also can print monitoring curve synchronously, designed with compact, light, stable in performance and have high dependability.
BD-300A/300B/300C series Disposable Syringe Destroyer can melt needle and destroy the syringe body at the same time within only 3-5 seconds, easy to operate.
.